Yokogawa YTA70 Temperature Transmitter

$500.00

The Yokogawa YTA70 is a smart temperature transmitter designed for precise and reliable temperature measurement in demanding industrial environments. It supports a wide range of RTD and thermocouple sensors and provides 4–20 mA output with digital communication options, enabling seamless integration into modern process control systems.

Typical Applications:
• Oil & gas processing plants
• Petrochemical and chemical industries
• Power generation facilities
• Refining and pipeline temperature monitoring
• Industrial process automation systems

Not Recommended For:
• Simple local temperature indication without transmitter output
• Basic low-cost OEM equipment where advanced diagnostics are unnecessary

YTA70 Temperature Transmitter

Selection Notes

• Confirm sensor type — supports RTDs such as Pt100 and common thermocouple types.
• Determine mounting configuration — typically installed in field instrument housings or control cabinets.
• Select communication protocol — available with standard 4–20 mA output and digital communication options.
• Verify environmental protection and hazardous area certification if required.

Why Choose the Yokogawa YTA70 Temperature Transmitter

• High Measurement Stability
Provides accurate and stable temperature measurement for critical industrial processes.

• Wide Sensor Compatibility
Supports various RTD and thermocouple inputs for flexible instrumentation setups.

• Advanced Communication Capability
Offers 4–20 mA output with digital communication support for integration with PLC and DCS systems.

• Industrial-Grade Reliability
Designed for continuous operation in harsh environments including vibration and temperature variations.

• Flexible System Integration
Easily integrated into existing process control systems used in large industrial facilities.

FAQ

Q: What types of sensors can the YTA70 work with?
A: It supports a wide range of RTD sensors (such as Pt100) and thermocouples used in industrial temperature measurement.

Q: What output signals are available?
A: The transmitter typically provides a 4–20 mA analog signal with digital communication capability depending on configuration.

Q: Is the YTA70 suitable for process industries?
A: Yes — it is widely used in oil & gas, petrochemical, power generation, and other process industries.

Q: Can it be integrated into PLC or DCS systems?
A: Yes — the standard industrial output and communication protocols make integration straightforward.

Product Type

Head-Mount Temperature Transmitter

Input Type

Thermocouple, RTD, Resistance, DC Millivolts

Output Signal

4 to 20 mA DC (with HART communication)

HART Protocol Version

HART 5 or HART 7 selectable

Accuracy

See Table 1 (varies by input type)

Cold Junction Compensation Accuracy

±1°C (for T/C only)

Ambient Temperature Effects

See Table 1

Power Supply Effects

±0.005% of FS per Volt

EMC Conformity

EN61326-1 Class A

EU RoHS Directive

EN IEC 63000

Maximum Zero Offset

±50% of selected maximum value

Input Resistance

10 MΩ (power on), 3 kΩ (power off)

Sensor Burnout Protection

High, Low, or value within 3.5 to 23 mA

Weight

50 g

Reviews

There are no reviews yet.

Be the first to review “Yokogawa YTA70 Temperature Transmitter”

Your email address will not be published. Required fields are marked *

Scroll to Top