SIEMENS SITRANS SITRANS FC520/540 7ME445 Coriolis Flow Meter For Liquids Gases Mixtures

$6,000.00

The SIEMENS SITRANS FC520/540 Coriolis Flow Meter delivers high-precision mass flow, density, and temperature measurement for a wide range of liquids, gases, and mixtures. Its robust design ensures reliable performance in demanding industrial processes, helping to optimize efficiency and control.

Catalog sheet SITRANS FC520/FC540 (7ME445)

Category: Brand:

SITRANS FC520/FC540 7ME445 Coriolis Flow Meter

The flowmeter systems of the SITRANS FC500 series are the universal Coriolis multi-parameter flowmeter for routine and hygienic applications.They are formed by one FCS500 sensor and one FCT transmitter:
• SITRANS FC520 is the combination of the FCS500 sensor and the FCT020 transmitter
• SITRANS FC540 is the combination of the FCS500 sensor and the FCT040 transmitter

Features:

• Dual curved AISI 316L stainless steel measuring tubes
• Process connection: flange, thread, or a selection of hygienic fittings
• Nominal sizes: DN 10 to DN 80
• Connection sizes: DN 8 to DN 125 (⅜” to 5″)
• Nominal flow rates: 1 600 to 170 000 kg/h (3 527 to 374 786 lb/h)
• FCS500 sensors can be combined with compact or remote transmitters
• Versatility with superior turndown and low pressure loss
• Hygienic specification for food and beverage, biotechnological and
pharmaceutical applications

Benefits

  • Choose your sensor based on your applications need and afterwards select the transmitter model based on the communication and performance requested.
  • The modular concept allows to find the right fit for your need.
  • Maximum accuracy due to calibration facility accredited according to ISO/IEC 17025
  • Tube health check (diagnostic verification) alerts of potential performance issues doe to process events, e.g. unwanted gas or vapor breakout & solid deposits building up in the tubes.
  • High measurement sensitivity & intelligent dynamic range keeps the measurement active even in demanding high damping cases.
  • Precise flow rate measurement of fluids and gases, multi-phase fluids and fluids with specific gas content using the Coriolis principle.

Compatible fluids
▪ Liquids
▪ Gases
▪ Mixtures, solutions, emulsions, suspensions, and slurries Primary measured variables
▪ Mass flow
▪ Density
▪ Temperature
Based on the primary measured quantities, the transmitter also calculates
▪ Volume flow
▪ Percent concentration (fraction) of a two-component mixture(FCT040 only)
▪ Partial component flow rate (net flow) of a mixture consisting of two components (FCT040 only) Bi-directional operation The mass flow, volume flow, and net flow measurements can be bidirectional. Measurement variables for NTEP approval
▪ Mass flow uni-directional
▪ Volume flow uni-directional
Feature overview
• Energy-efficient low pressure loss design with short tube paths and large tube diameter
• Cost-effective short face-to-face length or customized installation length options
• Batching function with batch leakage detection and batch control by transmitter for precise dosing
• Accurate density measurement and up to four advanced Concentration Measurement data sets
• Benefit from Viscosity function and capability to handle high viscous process fluids
• Hygienic design, self-draining in vertical installation, with hygienic approval options

SITRANS FCS500

The universal Coriolis flow sensor for routine and hygienic applications

  • Dual curved AISI 316L stainless steel tubes with polished option
  • Nominal sizes from DN10 to DN80
  • Process connection: flange, thread, or a selection of hygienic fittings
  • Hygienic approvals for food, beverage, and pharmaceutical sectors
  • Versatile solution with superior turndown and low pressure loss

SITRANS FCT020

  • Multilingual wizard for easy setup and guidance through the main configuration
  • Event Management as unique and useful support to run the process effectively and safely
  • Data mobility provided by microSD card for easy transfer to other devices for fast setup or to pc for in-depth process analysis or remote service
  • Widest range of I/O combinations in the market for most flexible adjustment to the existing system periphery
  • Universal power supply to install the device anywhere in the world
  • Hart, Modbus communication
  • NAMUR NE95 compliance, SIL 2 and SIL 3 compliance

SITRANS FCT040

  • Tube health check and key diagnostics for inline meter verification without disturbing running measurements
  • Extensive range of optional functions selectable at time of ordering
  • Batching function and Viscosity function
  • Dynamic Pressure Compensation for consistently accurate and stable measurement even with significant fluctuations in operating pressures
  • Inline concentration measurement
  • Integrated net oil computing acc. API standard
  • Hart, Modbus, Profibus PA communication
Measuring range

0.8 – 255000 kg/h

Maximum process temp.

-70 to +200 °C
-94 to +392 °F

Wetted materials

316L SS/1.4404

Sensor size

DN10 – DN80

Maximum pressure

Up to 100 bar
Up to 1450 psi

Approvals

– Ex-approvals
ATEX
IECEx
FM
Korea Ex
– Hygienic
3A
EHEDG
– Marine (class 2 and 3)
Det Norske Veritas
Lloyds Register
Bureaux Veritas
American Bureaux of
Shipping
Korean Register

Features

Functional Safety SIL2/3
Custody Transfer (NTEP)
Namur NE 21, NE 95
Tube Health Check

Reviews

There are no reviews yet.

Be the first to review “SIEMENS SITRANS SITRANS FC520/540 7ME445 Coriolis Flow Meter For Liquids Gases Mixtures”

Your email address will not be published. Required fields are marked *

You may also like…

Scroll to Top

📌                     【Big News】                 📌

Endress+Hauser product prices – unprecedented!

Effective immediately, we have secured the lowest-ever pricing on E+H products. Unbeatable value for money.

Contact us for a quote now. This great offer won’t last!