Endress+Hauser iTEMP TMT162 temperature transmitter

$880.00

Unsurpassed reliability, accuracy and long-term stability in critical processes. The remote configurable transmitter transfers and monitors converted signals from RTD sensors and thermocouples as well as from resistance and voltage signals using selectively HART®, FOUNDATION Fieldbus™-, PROFIBUS® PA-communication. It visualizes the signals on its own backlit display. A field housing allows a direct connection in harsh process areas as well as in hygienic applications as option.

iTEMP TMT162 temperature transmitter

HART®, FOUNDATION Fieldbus™ or PROFIBUS® temperature field transmitter with two universal sensor inputs suitable for use in hazardous areas and SIL 2

Specs at a glance

  • Accuracy

    (Pt100) <= 0,1 K (HART, FF, PA)
    (Pt100) <= 0,18 °F (HART, FF, PA)

Field of application

Unsurpassed reliability, accuracy and long-term stability in critical processes. The remote configurable transmitter transfers and monitors converted signals from RTD sensors and thermocouples as well as from resistance and voltage signals using selectively HART®, FOUNDATION Fieldbus™-, PROFIBUS® PA-communication. It visualizes the signals on its own backlit display. A field housing allows a direct connection in harsh process areas as well as in hygienic applications as option.

  • Universal input usable for resistance thermometer (RTD), thermocouple (TC), resistance thermometer (Ω), voltage transmitters (mV)

  • HART® protocol for converting various input signals to a scalable 4 to 20 mA analog output signal. Operating the transmitter using handheld terminals Field Xpert SFX350/370, field communicator 475 or remotely via PC

  • FOUNDATION Fieldbus™ ITK 6.1.2

  • PROFIBUS® PA Profile 3.02

  • Optional: stainless steel housing for hygienic or Ex d application

Benefits

  • High reliability in harsh industrial environments due to dual compartment housing and compact, fully potted electronics

  • Backlit display with large measured value, bar graph and status condition indication

  • Diagnostics information according to NAMUR NE107

  • International approvals such as FM, CSA (IS, NI, XP and DIP) and ATEX (Ex ia, Ex nA nL, Ex d and dust ignition-proof); marine approval

  • SIL certification as per IEC 61508:2010

  • Galvanic isolation 2 kV (sensor input / current output)

Measuring principle

Field transmitter

Input

2 x RTD, TC, Ohm, mV

Output

1 x analog 4…20 mA / HART
FOUNDATION Fieldbus H1
PROFIBUS PA

Auxiliary power supply

11,5…42 V DC (HART)
11,5…30 V DC (Ex ia)
9…32 V DC (FF, PA)
10,5…24 V DC (Ex ia, FF, PA)

Communication

HART
FOUNDATION Fieldbus
PROFIBUS PA

Installation

in field

Accuracy

(Pt100) <= 0,1 K (HART, FF, PA)
(Pt100) <= 0,18 °F (HART, FF, PA)

Galvanic isolation

yes

Certification

UL rec. Comp (HART)
marine approval only for HART-protocol
SIL2/3 only for HART-protocol
ATEX Ex ia, Ex d, Ex tb, Ex ic, Ex nA
ATEX IECEx Ex tb
IECEx Ex ia, Ex d, Ex tb
CSA IS, NI, XP, DIP
CSA General Purpose
FM IS, NI, XP, DIP
FM+CSA XP,DIP, IS, NI
INMETRO Ex ia, Ex db, Ex tb
NEPSI Ex ia, Ex nA, Ex d
EAC Ex ia, Ex d
UKCA Ex db, Ex ia, Ex nA

Reviews

There are no reviews yet.

Be the first to review “Endress+Hauser iTEMP TMT162 temperature transmitter”

Your email address will not be published. Required fields are marked *

Scroll to Top