FLOWSIC900 is the result of our many years of experience in natural gas measurement: a flowmeter specially tailored to the requirements of the LNG industry. It offers the required custody transfer accuracy for volume flow measurement and meets highest metrological standards. With FLOWSIC900 and the proven products FLOWSIC600-XT and FLOWSIC100 Flare-XT, we offer high-end measurement solutions from a single source to bring measurement performance and reliability in LNG plants to a new level.

FLOWSIC900 IFL900 ultrasonic flowmeter

Custody transfer ultrasonic LNG meter

Specs at a glance

  • Measured variables

    Volume a. c., volumetric flow a. c., Fluid velocity, Speed of sound

  • Measuring Medium

    LNG (Liquefied Natural Gas)

  • Nominal pipe size

    8 ″ … 36 ″
    DN200 … DN900, Schedule 40S/STD acc. ASME B36.19 / B36.10, others on request

Field of application

FLOWSIC900 is the result of our many years of experience in natural gas measurement: a flowmeter specially tailored to the requirements of the LNG industry. It offers the required custody transfer accuracy for volume flow measurement and meets highest metrological standards. With FLOWSIC900 and the proven products FLOWSIC600-XT and FLOWSIC100 Flare-XT, we offer high-end measurement solutions from a single source to bring measurement performance and reliability in LNG plants to a new level.

  • Custody transfer measurement of LNG

  • On- and offshore applications

  • Liquefaction, transport and storage of LNG

Device properties:

  • Intrinsically safe and reliable ultrasonic transducers

  • Conform to OIML R117 Cl. 0.3 and API MPMS Ch. 5.8

  • Real time measurement and diagnostics

  • Full bore design without pressure drop or need for flow conditioner

  • Factory thermal pre-insulation

  • Remote Signal Processing Unit

Benefits

  • Low measurement uncertainty directly at custody transfer point reducing financial risks during LNG-transaction

  • Increased transparency during LNG transaction by dynamic & real-time measurement &
    diagnostics

  • Operational expenditure savings by reduced boil-off gas losses and efficient LNG transfer due to minimized pressure drop

  • Capital expenditure savings by simpliefied meter integration and installation due to compact design and factory pre-insulation

  • Easy and fast access during commissioning and regular checks with remote SPU

Measuring principle

Ultrasonic transit time difference measurement

Measured variables

Volume a. c., volumetric flow a. c., Fluid velocity, Speed of sound

Measuring Medium

LNG (Liquefied Natural Gas)

Repeatability

≤ ± 0.05 % of the measured value

Accuracy

Typical error limits Qmin … Qmax
≤ ±0.2 % of reading
After flow calibration and adjustment

Operating pressure range

0 bar (g) … 19 bar (g) / 0 psi(g) … 275 psi(g)

Nominal pipe size

8 ″ … 36 ″
DN200 … DN900, Schedule 40S/STD acc. ASME B36.19 / B36.10, others on request

Metrological approvals and certificates

Metrological:
OIML R117 Class 0.3

Explosion protection:
IECEx: IEC 60079
cCSA: CAN/CSA C22.2 No. 60079
CSAus: UL 60079, UL 61010, UL 1203, FM3600

Pressure rating:
ASME: B16.5/B16.47, B36.19/B36.10

Other: API MPMS Ch. 5.8

For details see operating instructions

Hazardous area approvals

IECEx
Ex db ia [ia Ga] IIA T4 Gb

NEC/CEC (US/CA)
Class I, Division 2, Group D T4
Ex db ia [ia Ga] IIA T4 Gb
Class I, Zone 1, AEx db ia [ia Ga] IIA T4 Gb
Class I, Division 1, Group D T4

Digital Outputs

2 Digital output/Frequency output:
Others on request

Digital communication

Modbus RS-485 (2x)
Modbus RTU/ASCII
Blutooth
USB