Endress+Hauser FLOWSIC100 IFL100 ultrasonic flow measurement instrument

$4,200.00

FLOWSIC100 was designed for emission monitoring tasks. The “H” versions are suitable for stacks with large diameters and applications with high dust content. The ultrasonic transducers of the “PR” probe type are mounted with fixed path length on one sender/receiver unit (measuring probe). The “AC” versions have an innovative internal cooling and are suitable for gas temperatures up to 450 °C. The purged “Px” versions are used for gases with high concentrations of sticky or wet dust.

FLOWSIC100 IFL100 ultrasonic flow measurement instrument

Volume flow measuring devices for continuous emission monitoring

Specs at a glance

  • Measured variables

    Volumetric flow a. c., volumetric flow s. c., gas velocity, sound velocity, gas temperature

  • Measuring range

    Gas Velocity: 0 … ± 40 m/s

Field of application

FLOWSIC100 was designed for emission monitoring tasks. The “H” versions are suitable for stacks with large diameters and applications with high dust content. The ultrasonic transducers of the “PR” probe type are mounted with fixed path length on one sender/receiver unit (measuring probe). The “AC” versions have an innovative internal cooling and are suitable for gas temperatures up to 450 °C. The purged “Px” versions are used for gases with high concentrations of sticky or wet dust.

  • Emission monitoring in the chemical and hydrocarbon processing (HPI) industry

  • Emission measurement in the processing industry (cement, iron and steel, glass)

Device properties:

  • Rugged titanium converters for long service life

  • Corrosion-resistant material for use with aggressive gases (option)

  • Integrated measurement via duct diameter for types H, M, and S

  • Probe version PR for cost-saving, single-sided installation in duct

  • Automated operational check with zero and reference point test

Benefits

  • Reliable flow measurement for ducts with small up to very large diameters

  • No purge air required for applications with gas temperatures up to 260 °C

  • Minimum operating and maintenance costs

  • Accurate measuring results under difficult measuring conditions

  • Measurement without pressure loss, therefore no influences on the process

  • User-friendly operation via SOPAS ET software

  • Reliable function monitoring due to enhanced diagnosis

Measuring principle

Ultrasonic transit time difference measurement

Measured variables

Volumetric flow a. c., volumetric flow s. c., gas velocity, sound velocity, gas temperature

Measuring range

Gas Velocity: 0 … ± 40 m/s

Medium temperature range

–40 °C … +260 °C

Operating pressure range

–100 hPa … 100 hPa

Nominal pipe size

0,15 … 13m

Conformities

2001/80/EC (13. BImSchV)
2000/76/EC (17. BImSchV)
27. BImSchV
30. BImSchV
TA-Luft (Prevention of Air Pollution)
EN 15267
EN 14181
EN 16911-2
MCERTS
GOST

Outputs

1 output:
0/2/4 … 20 mA, + 750 Ω
Electrically isolated, up to five outputs when add-on modules are used (option)

Digital Outputs

5 relay outputs (change-over contacts), potential-free:
+ 48 V, 1 A
Safety extra-low voltage; for status signals "operation/malfunction", "limit value", "warning", "maintenance" and "check cycle"

Digital communication

ASCII RS-485 (via optional interface module)
RTU RS-485 (via optional interface module)
TCP (via optional interface module)
Profibus (Via optional interface module)

Reviews

There are no reviews yet.

Be the first to review “Endress+Hauser FLOWSIC100 IFL100 ultrasonic flow measurement instrument”