Selection Notes
• Confirm that the liquid is electrically conductive, which is required for electromagnetic measurement
• Verify the flow range, typically from 0.14 to 1.66 l/s depending on configuration
• Choose the correct hygienic connection, such as Tri-Clamp or threaded fittings
• Check the process temperature, up to 130 °C (or 150 °C with specific seals)
• In addition, ensure compliance with hygienic standards such as EHEDG or 3-A if required
Why Choose the Dosimag D5AB
• High Repeatability for Filling Processes
The sensor delivers repeatability up to ±0.25% of reading. Therefore, it ensures consistent filling accuracy in dosing applications.
• Hygienic Design with Full Cleanability
The fully welded housing and smooth surfaces support CIP and SIP cleaning. As a result, it meets strict hygienic requirements.
• Compact and Space-Saving Construction
Its ultra-compact design reduces installation space. Consequently, it is ideal for skid systems and OEM equipment.
• No Pressure Loss and Maintenance-Free Operation
The flowmeter has no internal obstructions or moving parts. This design eliminates pressure loss and reduces maintenance needs.
• Integrated Batching and Digital Communication
Optional features include IO-Link and Modbus communication. In addition, integrated batching functions improve filling control and process efficiency.
• High Chemical Resistance Materials
With PFA lining and corrosion-resistant electrodes, the device performs reliably in aggressive media.
FAQ
Q: What applications is Dosimag D5AB best suited for?
A: It is designed for filling, dosing and bottling processes in hygienic industries such as food, beverage and pharmaceuticals.
Q: What is the measurement principle?
A: It uses electromagnetic flow measurement based on Faraday’s law, ensuring accuracy independent of fluid properties.
Q: Does it support hygienic standards?
A: Yes. The device complies with EHEDG, 3-A and FDA requirements, and supports CIP/SIP cleaning.
Q: What communication options are available?
A: It supports pulse output, IO-Link and Modbus RS485, depending on configuration.






Reviews