SIEMENS SITRANS FC120/FC140 7ME441 Coriolis Flow Meter For Liquids Gases Mixtures

$4,800.00

The SIEMENS SITRANS FC120 and FC140 series are high-performance Coriolis mass flow meters designed for the precise measurement of liquids, gases, and mixture fluids. Known for their exceptional measurement accuracy and long-term stability, these meters are widely used in various demanding industrial processes to deliver reliable process data.

Catalog sheet SITRANS FC120/FC140 (7ME441)

SITRANS FC120/FC140 7ME441 Coriolis Flow Meter

The flowmeter systems of the SITRANS FC100 series are the precision Coriolis multi-parameter flowmeter for low flow applications.

They are formed by one FCS100 sensor and one FCT transmitter:

  • SITRANS FC120 is the combination of the FCS100 sensor and the FCT020 transmitter
  • SITRANS FC140 is the combination of the FCS100 sensor and the FCT040 transmitter

Features:

  • Compact dual curved alloy 22 measuring tubes
  • Process connection: flange, thread or hygienic clamp
  • Nominal sizes: DN 1 to DN 8
  • Connection sizes: DN 6 to DN 40 (¼” to 1½”)
  • Nominal flow rates: 21 kg/h to 950 kg/h (46 lb/h to 2 094 lb/h)
  • FCS100 sensors always combine with a remote transmitter via a connecting cable
  • Installation of sensor and transmitter in different locations

Benefits

  • Choose your sensor based on your applications need and afterwards select the transmitter model based on the communication and performance requested.
  • The modular concept allows to find the right fit for your need.
  • Maximum accuracy due to calibration facility accredited according to ISO/IEC 17025
  • Tube health check (diagnostic verification) alerts of potential performance issues doe to process events, e.g. unwanted gas or vapor breakout & solid deposits building up in the tubes.
  • High measurement sensitivity & intelligent dynamic range keeps the measurement active even in demanding high damping cases.
  • Precise flow rate measurement of fluids and gases, multi-phase fluids and fluids with specific gas content using the Coriolis principle.

Compatible fluids

  • Liquids
  • Gases
  • Mixtures, solutions, emulsions, suspensions and slurries

Primary measured variables

  • Mass flow
  • Density
  • Temperature

Based on the primary measured quantities, the transmitter also calculates

  • Volume flow
  • Percent concentration (fraction) of a two-component mixture (FCT040 only)
  • Partial component flow rate (net flow) of a mixture consisting of two components (FCT040 only)

The mass flow, volume flow, net flow measurements can be bi-directional.

Measurement variables for NTEP approval

  • Mass flow uni-directional
  • Volume flow uni-directional

Feature overview

  • Possibly the most compact dual curve Coriolis flowmeter for precision measurement, starting at DN 1 nominal size
  • Batching function with batch leakage detection and batch control by transmitter for precise dosing
  • Accurate density measurement and up to four advanced concentration measurement data sets
  • Sizes to suit pilot plants, R&D labs and high value fluid additives
  • Wide choice of process connections, starting with DN 6 (¼ inch) for reduced installation efforts

SITRANS FCS100

The precision Coriolis flow sensor for low flow applications

  • Possibly the most compact dual curve Coriolis flow sensor
  • Nominal sizes from DN1 to DN8
  • Process connection: flange, thread, or hygienic clamp
  • Install in tight spaces with no inlet and outlet restrictions
  • Sizes to suit pilot plants, R & D labs, and high value fluid additives

SITRANS FCT020

  • Multilingual wizard for easy setup and guidance through the main configuration
  • Event Management as unique and useful support to run the process effectively and safely
  • Data mobility provided by microSD card for easy transfer to other devices for fast setup or to pc for in-depth process analysis or remote service
  • Widest range of I/O combinations in the market for most flexible adjustment to the existing system periphery
  • Universal power supply to install the device anywhere in the world
  • Hart, Modbus communication
  • NAMUR NE95 compliance, SIL 2 and SIL 3 compliance

SITRANS FCT040

  • Tube health check and key diagnostics for inline meter verification without disturbing running measurements
  • Extensive range of optional functions selectable at time of ordering
  • Batching function and Viscosity function
  • Dynamic Pressure Compensation for consistently accurate and stable measurement even with significant fluctuations in operating pressures
  • Inline concentration measurement
  • Integrated net oil computing acc. API standard
  • Hart, Modbus, Profibus PA communication
Measuring range

0.01 – 1500 kg/h

Maximum process temp.

-50 to +260 °C
-58 to +500 °F

Wetted materials

Alloy 22/2.4602 and
316L/1.4404

Sensor size

DN1 – DN8

Maximum pressure

Up to 285 bar
Up to 4183 psi

Approvals

– Ex-approvals
ATEX
IECEx
FM
Korea Ex
– Marine (class 2 and 3)
Det Norske Veritas
Lloyds Register
Bureaux Veritas
American Bureaux of
Shipping
Korean Register

Features

Functional Safety SIL2/3
Custody Transfer (NTEP)
Namur NE 21, NE 95
Tube Health Check

Reviews

There are no reviews yet.

Be the first to review “SIEMENS SITRANS FC120/FC140 7ME441 Coriolis Flow Meter For Liquids Gases Mixtures”

Your email address will not be published. Required fields are marked *

Scroll to Top