Endress+Hauser iTEMP TMT84 temperature transmitter

$320.00

Unsurpassed reliability, accuracy and long-term stability in critical processes over all industries. The configurable transmitter not only transfers digital converted signals from RTD and TC sensors, it also transfers resistance and voltage signals using PROFIBUS® PA communication. High measurement point availability by means of sensor monitoring functions. Diagnostics information according to NAMUR NE 107. Optimization of the measurement accuracy by sensor-transmitter matching.

iTEMP TMT84 temperature transmitter

PROFIBUS® temperature transmitter as head or field device with two universal sensor inputs suitable for use in hazardous areas

Specs at a glance

  • Accuracy

    (Pt100) <= 0,1 K
    (Pt100) <= 0,18 °F

Field of application

Unsurpassed reliability, accuracy and long-term stability in critical processes over all industries. The configurable transmitter not only transfers digital converted signals from RTD and TC sensors, it also transfers resistance and voltage signals using PROFIBUS® PA communication. High measurement point availability by means of sensor monitoring functions. Diagnostics information according to NAMUR NE 107. Optimization of the measurement accuracy by sensor-transmitter matching.

  • 2 input channels and PROFIBUS® PA protocol for the conversion of input signals into digital output signals

  • The device stands out due to signal reliability, long-term stability, high precision and advanced diagnostics (important in critical processes)

  • For the highest level of safety, availability and risk reduction

  • Installation in flat-face terminal head as per DIN EN 50446

  • Optional installation in field housings even for use in Ex d areas – with mounting brackets for wall or pipe mounting

Benefits

  • Easy and standardized communication via PROFIBUS® PA Profile 3.02

  • Meets the EMC requirements as per NAMUR NE 21 and the recommendations of NE 89 with regard to temperature transmitters with digital signal processing

  • Straightforward design of measuring points in Ex-areas through FISCO/FNICO conformity in accordance with IEC 600079-27

  • Safe operation in hazardous areas thanks to international approvals such as FM IS, NI, CSA IS, NI as well as ATEX Ex ia, Ex nA (Ex nL)

  • High accuracy through sensor-transmitter matching

  • Reliable operation with sensor monitoring and device hardware fault recognition

  • Rapid no-tools wiring due to optional spring terminal technology

Measuring principle

Head transmitter

Input

2 x RTD, TC, Ohm, mV

Output

PROFIBUS PA

Auxiliary power supply

9…32 V DC (PROFIBUS PA)
9…17,5 V DC (FISCO/FNICO)

Communication

PROFIBUS PA

Installation

Terminal head form B

Accuracy

(Pt100) <= 0,1 K
(Pt100) <= 0,18 °F

Galvanic isolation

yes

Certification

ATEX Ex ic, Ex tb, Ex ia, Ex nA,Ex tc, Ex d
ATEX IECEx Ex ia
IECEx Ex ia, Ex tb, Ex d
CSA C/US General Purpose
CSA IS, NI, XP, DIP
FM IS, NI, XP, DIP
FM+CSA IS, NI
INMETRO Ex ia [ia Ga], Ex d, Ex tb
NEPSI Ex ia, Ex d, Ex tb
EAC Ex ia, Ex d
UKCA Ex tb, Ex tc, Ex ia, Ex nA, Ex db

Reviews

There are no reviews yet.

Be the first to review “Endress+Hauser iTEMP TMT84 temperature transmitter”

Your email address will not be published. Required fields are marked *

Scroll to Top