Endress+Hauser Electronic differential pressure Deltabar FMD72

$2,800.00

The electronic dp Deltabar FMD72 is a differential pressure system, used to measure the pressure, level, volume or mass of liquids in pressurized tanks or distillation columns/evaporators. The high pressure sensor (HP) measures the hydrostatic pressure. The low pressure sensor (LP) measures the head pressure. The level is calculated in the transmitter using these two digital values. The electronic dp system eliminates issues of traditional differential pressure measurements.

Electronic differential pressure Deltabar FMD72

Electronic differential pressure system utilizing two metal sensor modules and one transmitter

Specs at a glance

  • Accuracy

    0.075% of individual sensor,
    “PLATINUM” 0.05% of individual sensor

  • Process temperature

    –40…+125°C
    (–40 … +257°F)

  • Pressure measuring range

    400 mbar…10 bar
    (6 psi…150 psi)

  • Process pressure / max. overpressure limit

    160 bar (2400 psi)

  • Main wetted parts

    316L, Alloy C

  • Material process membrane

    316L, AlloyC,

  • Measuring cell

    400 mbar…10 bar
    (6 psi…150psi)

Field of application

The electronic dp Deltabar FMD72 is a differential pressure system, used to measure the pressure, level, volume or mass of liquids in pressurized tanks or distillation columns/evaporators. The high pressure sensor (HP) measures the hydrostatic pressure. The low pressure sensor (LP) measures the head pressure. The level is calculated in the transmitter using these two digital values. The electronic dp system eliminates issues of traditional differential pressure measurements.

For differential pressure, level, volume or mass measurement of liquids in pressurized tanks and distillation columns/evaporators.

  • Process connections: Threads, flanges and hygienic connections

  • Process temperature: -40 to +125°C (-40 to +257°F), optional 250°C (480°F)

  • Measuring range: 400mbar to +40bar (6 to 600psi)

  • Accuracy: Single sensor up to ±0.05%, system up to ±0.07%

  • International explosion protection certificates, hygienic

Benefits

  • Eliminates traditional mechanical issues resulting in greater process availability and reliability

  • Safety risks are minimized with the new electronic differential pressure system architecture and design

  • Lowest total cost of ownership due to reduced installation time, maintenance, downtime and spare requirements

  • Multivariable level measurement: HART-based differential pressure, head pressure and sensor temperatures from one system

  • Continuous health indication of the entire system via HART-based diagnostic

  • High reproducibility and long-term stability

  • Process safety assured with small flush mounted process connections in hygienic applications

 

Measuring principle

Differential pressure

Characteristic

Electronic differential pressure transmitter with metal sensor for level, volume or mass measurement in liquids.

Supply voltage

4…20 mA HART:
12…45V DC (Non Ex)
Ex ia: 12…30V DC

Reference Accuracy

0.075% of individual sensor,
"PLATINUM" 0.05% of individual sensor

Long term stability

0.05% of URL/year of individual sensor

Process temperature

–40…+125°C
(–40…+257°F)

Ambient temperature

–40…+80°C
(–40…+176°F)

Measuring cell

400 mbar…10 bar
(6 psi…150psi)

Vacuum resistance

10 mbar (0.15 psi)

Max. overpressure limit

160 bar (2400 psi)

Process connection

Threads
Flange (DIN, ASME,JIS)

Process connection hygienic

DIN11851
DIN11864-1
Tri-Clamp
DRD
Varivent

Material process membrane

316L, AlloyC,

Fill fluid

Silicone oil
Synthetic oil

Material housing

Die-cast aluminum
Stainless steel

Communication

4…20 mA HART

Certificates / Approvals

ATEX, FM, CSA, IECEx, NEPSI, INMETRO, UK Ex

Design approvals

NACE MR0175,
EN10204-3.1,

Hygienic approvals

EHEDG
3A