Endress+Hauser Capacitance Point level detection Minicap FTC260

$300.00

Minicap FTC260 is a simple and cost-effective rod probe for point level detection in bulk solids, particularly suited to applications involving aggressive media and heavy build-up. It is designed for point level detection of light bulk solids, e.g. grain products, flour, milk powder, animal feed, cement, chalk or gypsum.

Capacitance Point level detection Minicap FTC260

Designed for light bulk solids

Specs at a glance

  • Process temperature

    -40°C …+120°C
    (-40°F …+248°F)

  • Process pressure / max. overpressure limit

    -1 … 25 bar
    (-14.5 … 360 psi)

Field of application

Minicap FTC260 is a simple and cost-effective rod probe for point level detection in bulk solids, particularly suited to applications involving aggressive media and heavy build-up. It is designed for point level detection of light bulk solids, e.g. grain products, flour, milk powder, animal feed, cement, chalk or gypsum.

For point level detection of light bulk solids, with a grain size up to max. 30mm and a dielectric constant εr ≥ 1.6.
Typical applications: Grain products, flour, milk powder, animal feed, cement, chalk or gypsum.

  • Process connection: Threads

  • Temperature: -40 to +80°C (-40 to +176°F)

  • Pressure: -1 to +25bar (-14.5 to +360psi)

  • Sensor length: 140mm (5.51″)

  • International explosion protection certificates, overfill prevention WHG

Benefits

  • Simple mounting and commissioning without calibration

  • Mechanical safety, cost-efficiency and long operating life due to no wearing parts

  • High operational safety and reliability due to active build-up compensation

 

Measuring principle

Capacitive Solid

Characteristic / Application

Compact rod probe with build-up compensation
easy start up

Specialities

FDA-listed material

Supply / Communication

10,8 … 45V DC, DC-PNP 3-wire
20 … 253V AC, or
20 … 55V DC, Relay output

Ambient temperature

-40°C…+70°C
(-40°F…+158°F)

Process temperature

-40°C …+120°C
(-40°F …+248°F)

Process pressure / max. overpressure limit

-1 … 25 bar
(-14.5 … 360 psi)

Main wetted parts

PPS = Polyphenylene sulphide
(glass fibre content approx. 40%)

Process connection

R1"
NPT1"

Sensor length

140 mm (5.51")

Communication

PNP transistor output
Relay output (potential-free
change-over contact / SPDT)

Certificates / Approvals

ATEX , IEC Ex, FM, CSA, NEPSI, UK Ex

Options

Aluminium Housing

Application limits

Solids, grain size max. 30 mm (1.2"),
DK min 1,6
Flexural strength 1400 N (at probe tip)