Endress+Hauser Capacitance Point level detection Liquicap FTI51

$1,000.00

Liquicap FTI51 is a rod probe for point level detection of liquids that are highly viscous and tend to form build-up. Also used for detection of interface and foam of conductive liquids. Due to its active build-up compensation FTI51 offers maximum reliability and is suited for a wide range of applications thanks to international certificates. The parts in contact with the process are made of corrosion-resistant and FDA-listed materials – this guarantees a high safety standard.

Capacitance Point level detection Liquicap FTI51

For liquids that are highly viscous and tend to form build-up

Specs at a glance

  • Process temperature

    -80 °C … +200 °C
    (-112 °F … +392 °F)

  • Process pressure / max. overpressure limit

    Vacuum … 100 bar
    (Vacuum … 1450 psi)

Field of application

Liquicap FTI51 is a rod probe for point level detection of liquids that are highly viscous and tend to form build-up. Also used for detection of interface and foam of conductive liquids. Due to its active build-up compensation FTI51 offers maximum reliability and is suited for a wide range of applications thanks to international certificates. The parts in contact with the process are made of corrosion-resistant and FDA-listed materials – this guarantees a high safety standard.

For liquids that tend to form build-up. Interface detection of different liquids. Two-point control (pump control) with just one process connection. Foam detection of conductive liquids.

  • Process connections: Flanges, threads, special hygienic process connections

  • Temperature: -80 to +200°C (-112 to +392°F)

  • Pressure: Vacuum to +100bar (vacuum to +1,450psi)

  • Sensor length: 6m (20ft)

  • International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approval

Benefits

  • Cost savings thanks to easy and fast commissioning as calibration takes place at the press of a button

  • Reliable and safe measurement due to active build-up compensation

  • Reliable and universal application thanks to wide range of certificates and approvals

  • Short reaction time

  • Material in contact with the process made of corrosion-resistant and FDA-listed materials

  • Two-stage overvoltage protection

  • No need for recalibration after replacing electronics

Measuring principle

Capacitive Liquid

Characteristic / Application

Capacitive rod probe

Specialities

Interface detection
Foam detection

Ambient temperature

-50 °C … +70 °C
(-58 °F … +158 °F)
With separate housing:
-50 °C … +120 °C
(-58 °F … +248°F)

Process temperature

-80 °C … +200 °C
(-112 °F … +392 °F)

Process pressure / max. overpressure limit

Vacuum … 100 bar
(Vacuum … 1450 psi)

Main wetted parts

Insulation material: PTFE, PFA
316L

Process connection

G 1/2 … 1 1/2
NPT 1/2 … 1 1/2
Flange from DN25…/ASME 1"…/JIS 10K…

Process connection hygienic

Tri-Clamp ISO2852 gap free plated
Dairy coupling
Flush mount

Sensor length

Total length of probe: max 6 m (20 ft)

Communication

2- wire 19-253 VAC
3-wire
PFM
Relay DPDT
DC-PNP
8/16 mA

Certificates / Approvals

ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI, EAC

Safety approvals

Overfill prevention WHG
SIL

Design approvals

EN 10204-3.1
NACE MR0175

Marine approval

GL/ ABS/ DNV

Options

Inactive length
Fully isolated active build-up compensation
Ground tube
Separate housing

Components

Transmitter
PFM: FTC325, FTC625, FTC470Z, FTC471Z
3-wire:
FTC325

Application limits

Notice the pressure and temperature derating.
Notice for non conductive medium the DK.

Reviews

There are no reviews yet.

Be the first to review “Endress+Hauser Capacitance Point level detection Liquicap FTI51”

Your email address will not be published. Required fields are marked *